System controller (version NB-IoT)
Controller is intended for use as part of security, fire, emergency and other types of security system, as well as the controller of a smart home at the facility.
Controller is intended for use as part of security, fire, emergency and other types of security system, as well as the controller of a smart home at the facility.
Controller is intended for:
 – data exchange with wireless devices via 433 MHz radio channel,
 – control of hardwired detectors connected to the hardwired zones,
 – execution of up to 10 preset home automation scripts,
 – data exchange between the protected object and the server through TCP / IP networks (Internet): LTE Cat Nb1 (NB-IoT) and Ethernet in encrypted form.
| Name | Description | 
|---|---|
| Wireless coverage range | 100 m | 
| Operating frequency | 433 MHz | 
| Powering from external power supply: | |
| - voltage of the main (terminals + 12V-) and backup (terminals + 12VR-) power supply | 10.5 to 13.6 V | 
| max current consumption | 300 mA | 
| rated current consumption | 150 mA | 
| Powering from USB adapter: | |
| mains power voltage | 110 to 240 V AC | 
| power consumption | 5 W | 
| voltage of the adapter | 5 V +/- 5% | 
| max current consumption | 500 mA | 
| rated current consumption | 200 mA | 
| Powering from backup battery: | |
| battery voltage | 3.3 to 4.2 V | 
| average lifetime of the battery | 4 to 8 hours | 
| battery charge time | 10 hours | 
| Hardwire zone resistance (intrusion type): | |
| Norm | 3 to 5 kOhm | 
| Alarm | 0 to 3 and more than 5 kOhm | 
| Hardwire zone resistance (fire alarm type): | |
| Norm | 3 to 5 kOhm | 
| Fire alarm | 1.5 to 3 and 5 to 12 kOhm | 
| Failure | 0 to 1.5 and more than 12 kOhm | 
| Hardwire zone resistance (fire alarm type double event): | |
| Norm | 3 to 5 kOhm | 
| Fire alarm | 0 to 1.5 and 5 to 12 kOhm | 
| fire danger | 1.5 to 3 kOhm | 
| Failure | more than 12 kOhm | 
| Relays specification: | |
| Max load voltage | 100 V | 
| Max load current | 0.1 A | 
| Open collector specification: | |
| Max load voltage | 24 V | 
| Max load current | 0.25 A | 
| Boot time | 60 sec | 
| Max length of TM | 15 m | 
| Overall dimensions | 136 × 86 × 38 mm | 
| Weight | 0.14 kg | 
| Temperature range | -10 to +50 °С | 
| Relative air humidity | up to 98% at +40 °С |